Web Analytics
Datasheet 搜索 > Omron(欧姆龙) > 3G3MX2-A2007-E 数据手册 > 3G3MX2-A2007-E 数据手册 6/16 页
3G3MX2-A2007-E
2802.263
导航目录
3G3MX2-A2007-E数据手册
Page:
of 16 Go
若手册格式错乱,请下载阅览PDF原文件
MX2 9
Type designation
200 V class
400 V class
Specifications
Single-phase: MX2@ AB001 AB002 AB004 AB007
1
1. Single phase model use forced air cooling but three phase model is self cooling.
AB015 AB022 - - - - -
Three-phase: MX2@ A2001 A2002 A2004 A2007 A2015 A2022 A2037 A2055 A2075 A2011 A2150
Motor
kW
2
2. Based on a standard 3-Phase standard motor.
For VT setting 0.2 0.4 0.55 1.1 2.2 3.0 5.5 7.5 11 15 18.5
For CT setting 0.1 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15
Output
characteristics
Inverter capacity kVA
200 VT
0.4 0.6 1.2 2.0 3.3 4.1 6.7 10.3 13.8 19.3 23.9
200 CT
0.2 0.5 1.0 1.7 2.7 3.8 6.0 8.6 11.4 16.2 20.7
240 VT
0.4 0.7 1.4 2.4 3.9 4.9 8.1 12.4 16.6 23.2 28.6
240 CT
0.3 0.6 1.2 2.0 3.3 4.5 7.2 10.3 13.7 19.5 24.9
Rated output current (A) at VT 1.2 1.9 3.5 6.0 9.6 12.0 19.6 30.0 40.0 56.0 69.0
Rated output current (A) at CT 1.0 1.6 3.0 5.0 8.0 11.0 17.5 25.0 33.0 47.0 60.0
Max. output voltage Proportional to input voltage: 0..240 V
Max. output frequency 1000 Hz
3
3. Above 400Hz with some function limitation.
Power
supply
Rated input voltage
and frequency
Single-phase 200..240 V 50/60 Hz
3-phase 200..240 V 50/60 Hz
Allowable voltage fluctuation -15%..+10%
Allowable frequency fluctuation 5%
Braking torque
At short-time
deceleration
At capacitor
feedback
100%: <50Hz
50%: <60Hz
70%:
<50Hz
50%:
<60Hz
Approx 20% -
Cooling method
Self cooling
Forced-air-cooling
Three-phase: MX2@ A4004 A4007 A4015 A4022 A4030 A4040 A4055 A4075 A4110 A4150
Motor
kW
1
1. Based on a standard 3-Phase standard motor.
For VT setting 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5
For CT setting 0.4 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15
Output
characteristics
Inverter capacity kVA
380 VT
1.3 2.6 3.5 4.5 5.7 7.3 11.5 15.1 20.4 25.0
380 CT
1.1 2.2 3.1 3.6 4.7 6.0 9.7 11.8 15.7 20.4
480 VT
1.7 3.4 4.4 5.7 7.3 9.2 14.5 19.1 25.7 31.5
480 CT
1.4 2.8 3.9 4.5 5.9 7.6 12.3 14.9 19.9 25.7
Rated output current (A) at VT 2.1 4.1 5.4 6.9 8.8 11.1 17.5 23.0 31.0 38.0
Rated output current (A) at CT 1.8 3.4 4.8 5.5 7.2 9.2 14.8 18.0 24.0 31.0
Max. output voltage Proportional to input voltage: 0..480 V
Max. output frequency 1000 Hz
2
2. Above 400Hz with some function limitation.
Power
supply
Rated input voltage
and frequency
3-phase 380..480 V 50/60 Hz
Allowable voltage
fluctuation
-15%..+10%
Allowable frequency
fluctuation
5%
Braking torque
At short-time
deceleration
*3
At capacitor
feedback
100%: <50Hz
50%: <60Hz
70%:
<50Hz
50%:
<60Hz
-
Cooling method
Forced-air-cooling
MX2 series
A: Standard specs
MX2AB002-E
Voltage:
B: Single-phase 200 VAC
2: Three-phase 200 VAC
4: Three-phase 400 VAC
Max. applicable motor output
002: 0,2 kW
~
150: 15,0 kW
E: Europe standard

3G3MX2-A2007-E 数据手册

Omron(欧姆龙)
16 页 / 3.37 MByte

3G3MX2A2007 数据手册

Omron(欧姆龙)
Omron(欧姆龙)
Omron(欧姆龙)
电机驱动器 AC Drive 240V 3PH 1HP 0.7KW CT
器件 Datasheet 文档搜索
器件加载中...
AiEMA 数据库涵盖高达 72,405,303 个元件的数据手册,每天更新 5,000 多个 PDF 文件