ADC
´
´
Shunt Voltage
Channel
Bus Voltage
Channel
Shunt Voltage
(1)
Data Registers
Calibration
(2)
Current
(1)
Bus Voltage
(1)
Power
(1)
INA226
SBOS547A JUNE 2011REVISED AUGUST 2015
www.ti.com
7 Detailed Description
7.1 Overview
The INA226 is a digital current sense amplifier with an I
2
C- and SMBus-compatible interface. It provides digital
current, voltage, and power readings necessary for accurate decision-making in precisely-controlled systems.
Programmable registers allow flexible configuration for measurement resolution as well as continuous-versus-
triggered operation. Detailed register information appears at the end of this data sheet, beginning with Table 4.
See the Functional Block Diagram section for a block diagram of the INA226 device.
7.2 Functional Block Diagram
(1) Read-only
(2) Read/write
7.3 Feature Description
7.3.1 Basic ADC Functions
The INA226 device performs two measurements on the power-supply bus of interest. The voltage developed
from the load current that flows through a shunt resistor creates a shunt voltage that is measured at the IN+ and
IN– pins. The device can also measure the power supply bus voltage by connecting this voltage to the VBUS pin.
The differential shunt voltage is measured with respect to the IN– pin while the bus voltage is measured with
respect to ground.
The device is typically powered by a separate supply that can range from 2.7 V to 5.5 V. The bus that is being
monitored can range in voltage from 0 V to 36 V. Based on the fixed 1.25-mV LSB for the Bus Voltage Register
that a full-scale register results in a 40.96 V value.
NOTE
Do not apply more than 36 V of actual voltage to the input pins.
There are no special considerations for power-supply sequencing because the common-mode input range and
power-supply voltage are independent of each other; therefore, the bus voltage can be present with the supply
voltage off, and vice-versa.
The device takes two measurements, shunt voltage and bus voltage. It then converts these measurements to
current, based on the Calibration Register value, and then calculates power. Refer to the Programming the
Calibration Register section for additional information on programming the Calibration Register.
10 Submit Documentation Feedback Copyright © 2011–2015, Texas Instruments Incorporated
Product Folder Links: INA226

INA226AIDGST 数据手册

TI(德州仪器)
38 页 / 1.04 MByte
TI(德州仪器)
39 页 / 1.25 MByte

INA226 数据手册

TI(德州仪器)
TEXAS INSTRUMENTS  INA226AIDGSR  芯片, 放大器, 检流, MSOP-10
TI(德州仪器)
TEXAS INSTRUMENTS  INA226AIDGST  电流检测放大器, 双向电流, 1个放大器, 10 µA, MSOP, 10 引脚, -40 °C, 125 °C
TI(德州仪器)
具有警报功能的 AEC-Q100、36V、16 位、超精密、I2C 输出电流/电压/功率监控器 10-VSSOP -40 to 125
TI(德州仪器)
评估板, 双向, 超高精度, 低/高压侧, I2C输出电流/功率监视器
TI(德州仪器)
支持报警功能的汽车类 36V、超高精度、低侧/高侧、I2C 输出电流/功率监控器
器件 Datasheet 文档搜索
器件加载中...
AiEMA 数据库涵盖高达 72,405,303 个元件的数据手册,每天更新 5,000 多个 PDF 文件