Web Analytics
Datasheet 搜索 > 电源监控芯片 > TI(德州仪器) > TPS3510P 数据手册 > TPS3510P 数据手册 6/18 页
TPS3510P
器件3D模型
4.576
导航目录
TPS3510P数据手册
Page:
of 18 Go
若手册格式错乱,请下载阅览PDF原文件

   
SLVS312A JULY 2000 REVISED DECEMBER 2002
6
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
power supply remote on/off (PSON) and fault protect output (FPO)(continued)
When the FPO
signal is held high due to an occurring fault condition, the fault status is latched and the outputs
of the main power rails should not deliver current but are held at 0 V. Toggling the power supply remote on/off
(PSON
) from low to high resets the fault-protection latch. During this fault condition only the standby power is
not affected.
When PSON
goes from high to low or low to high, the 38-ms debounce block is active to avoid a glitch on the
input that disables/enables the FPO
output. During this period the under-voltage function is disabled for 75 ms
to prevent turnon failure. At turnoff, there is an additional delay of 2.3 ms from PSON
to FPO.
Power should be delivered to the rails only if the PSON
signal is held at ground potential, thus FPO is active-low.
The FPO
pin can be connected to 5 V (or up to 15 V) through a pullup resistor.
undervoltage protection
The TPS3510/1 provides under-voltage protection (UVP) for the 3.3-V and 5-V rails. When an undervoltage
condition appears at either one of the 3.3-V (VS33) or 5-V (VS5) input pins for more than 146 µs, the FPO
output
goes high and PGO goes low. Also, this fault condition is latched until PSON
is toggled from low to high or V
DD
is removed.
The need for undervoltage protection is often overlooked in off-line switching power supply system design. But
it is very important in battery-powered or hand-held equipment since the TTL or CMOS logic often results in
malfunction.
In flyback or forward-type off-line switching power supplies, usually designed for low power, the overload
protection design is very simple. Most of these types of power supplies are only sensing the input current for
an overload condition. The trigger point needs to be set much higher than the maximum load in order to prevent
false turnon.
However, this causes one critical problem. If the connected load is larger than the maximum allowable load but
smaller than the trigger point, the system always becomes overheated with failure and damage occurring.
overvoltage protection
The overvoltage protection (OVP) of TPS3510/1 monitors 3.3 V, 5 V, and 12 V (12 V is sensed via the V
DD
pin).
When an overvoltage condition appears at one of the 3.3-V, 5-V, or 12-V input pins for more than 73 µs, the FPO
output goes high and PGO goes low. Also, this fault condition is latched until PSON is toggled from low to high
or V
DD
is removed. During fault conditions, most power supplies have the potential to deliver higher output
voltages than those normally specified or required. In unprotected equipment, it is possible for output voltages
to be high enough to cause internal or external damage of the system. To protect the system under these
abnormal conditions, it is common practice to provide overvoltage protection within the power supply.
Because TTL and CMOS circuits are very vulnerable to overvoltages, it is becoming industry standard to provide
overvoltage protection on all 3.3-V and 5-V outputs. However, not only the 3.3-V and 5-V rails for the logic circuits
on the motherboard need to be protected, but also the 12-V peripheral devices such as the hard disk, floppy
disk, and CD-ROM players etc., need to be protected.
short-circuit power supply turnon
During safety testing the power supply might have tied the output voltage direct to ground. If this happens during
the normal operating, this is called a short-circuit or over-current condition. When it happens before the power
supply turns on, this is called a short-circuit power supply turnon. It can happen during the design period, in the
production line, at quality control inspection or at the end user. The TPS3510/1 provides an undervoltage
protection function with a 75-ms delay after PSON
is set low.

TPS3510P 数据手册

TI(德州仪器)
18 页 / 0.51 MByte

TPS3510 数据手册

TI(德州仪器)
用于开关模式电源的 3 通道监控器
TI(德州仪器)
MPU 监控和重置电路,Texas Instruments,双/多/可调Texas Instruments 微处理器电源电压监控和重置电路,具有双、多和可调阈值级别。### 微处理器电源电压监控和复位电路电源电压监测和监控电路,用于台式机、便携式计算机和笔记本电脑、测试和测量仪器、便携式电池供电设备和多输出电源。电源电压探测器 电源电压监控器 电源监控器 微处理器监控 微处理器电压监控器 微控制器复位电路
TI(德州仪器)
TEXAS INSTRUMENTS  TPS3510DR  电压监控器, 低电平有效, 漏极开路复位, 3监视器, 4V-15V输入, SOIC-8
TI(德州仪器)
监控电路 3.5V Pwr Supply Mntr
TI(德州仪器)
TEXAS INSTRUMENTS  TPS3510D  监控器, 低电平有效, 漏极开路复位, 3监视器, 4V-15V输入, SOIC-8
TI(德州仪器)
TEXAS INSTRUMENTS  TPS3510PE4  芯片, 3通道监控器
TI(德州仪器)
TI(德州仪器)
监控和复位芯片 TPS3510PG4 PDIP-8
器件 Datasheet 文档搜索
器件加载中...
AiEMA 数据库涵盖高达 72,405,303 个元件的数据手册,每天更新 5,000 多个 PDF 文件