Datasheet 搜索 > 电压监控芯片 > TI(德州仪器) > TPS3702CX50QDDCRQ1 数据手册 > TPS3702CX50QDDCRQ1 数据手册 3/28 页
TPS3702CX50QDDCRQ1
9.232
导航目录
TPS3702CX50QDDCRQ1数据手册
Page:
of 28 Go
若手册格式错乱,请下载阅览PDF原文件
1
2
3
6
5
4
VDD
SET
GND
SENSE
UV OV
TPS3702-Q1
www.ti.com
SBVS261B APRIL 2015REVISED DECEMBER 2015
5 Pin Configuration and Functions
DDC Package
SOT-6
Top View
Pin Functions
PIN
I/O DESCRIPTION
NO. NAME
Active-low, open-drain undervoltage output. This pin goes low when the SENSE voltage falls
1 UV O below the internally set undervoltage threshold (V
IT–
). See the timing diagram in Figure 1 for
more details. Connect this pin to a pull-up resistor terminated to the desired pull-up voltage.
2 GND Ground
Input for the monitored supply voltage rail. When the SENSE voltage goes below the
3 SENSE I undervoltage threshold, the UV pin is driven low.
When the SENSE voltage goes above the overvoltage threshold, the OV pin is driven low.
Use this pin to configure the threshold voltages.
4 SET I
Refer to Table 3 for the desired configuration.
Supply voltage input pin. To power the device, connect a voltage supply (within the range of 2 V
5 VDD I and 18 V) to VDD.
Good analog design practice is to place a 0.1-μF ceramic capacitor close to this pin.
Active-low, open-drain overvoltage output. This pin goes low when the SENSE voltage rises
6 OV O above the internally set overvoltage threshold (V
IT+
). See the timing diagram in Figure 1 for more
details. Connect this pin to a pull-up resistor terminated to the desired pull-up voltage.
Copyright © 2015, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Links: TPS3702-Q1

TPS3702CX50QDDCRQ1 数据手册

TI(德州仪器)
28 页 / 1.05 MByte
TI(德州仪器)
26 页 / 1.17 MByte

TPS3702CX50 数据手册

TI(德州仪器)
用于过压和欠压监测的汽车类高精度窗口电压检测器 6-SOT-23-THIN -40 to 125
TI(德州仪器)
用于过压和欠压监测的高精度窗口电压检测器 6-SOT-23-THIN -40 to 125
TI(德州仪器)
TEXAS INSTRUMENTS  TPS3702CX50DDCT  电压监控器, 低电平有效, 漏极开路复位, 2V-18V输入, SOT-23-6
器件 Datasheet 文档搜索
器件加载中...
AiEMA 数据库涵盖高达 72,405,303 个元件的数据手册,每天更新 5,000 多个 PDF 文件